Agilent Analysis of Vulcanized Rubber Formulations on the 500-MS Ion Trap Mass Spectrometer and Confirmation of Expected Structures Using TurboDDS? with ACD/MS Manager Software Application Note 1
Agilent Fast Analysis of Phenoxyacetic and Phenoxypropionic Herbicides in Vegetable Matrix by Negative Ion Electrospray LC/MS/MS Application Note 1
Agilent Analysis of Bumetanide in a Dietary Supplement Using the 500-MS Ion Trap Mass Spectrometer Application Note 本应用笔记描述了如何使用Varian 500-MS离子阱质谱仪在正负离子模式下分析补充剂中布美他尼
Agilent Quantitation of Multi-Class Pharmaceuticals in Water Using Simultaneous Positive and Negative ESI on the 320-MS Triple Quadrupole Mass Spectrometer Application Note 本文档介绍了一种在Varian 320-MS三重四极质谱仪上使用同时的正负ESI方法来定量水中多类药物的技术
Agilent Toxicological Screening with the Agilent 6500 Series Accurate-Mass Q-TOF LC/MS and the Personal Compound Database and Library using the Broecker, Herre and Pragst Accurate Mass Spectral Librar 1
Agilent Microimaging Applications in Industry - Curing of Plaster Cement Studied by MRI Application Note 本应用笔记介绍了微成像技术在工业应用中的应用,特别是使用 MRI 研究石膏水泥固化过程的案例。
Agilent Trace Level Analysis of Epichlorohydrin in Drinking Water by Gas Chromatography/Flame Ionization Detector Application Note 这份文件介绍了一种快速、经济、敏感和可靠的方法,用于测定饮用水中的氯氧丙烯。通过氯化亚甲基提取,然后用K-D浓缩器快速浓缩微量氯氧丙烯。使用Agilent 7890A GC系统和Agilent J&W DB-5ms超惰性柱进行氯氧丙烯分析。校准曲线在0.08-1.60 ng范围内线性,相关系数大于0.9997。在1.0和5.0 µg/L的添加水平下,氯氧丙烯的回收率分别为104.7%和107.0%。氯氧丙烯的重复性的RSD值小于2.21%。检测限低于0.07 µg/L,低于欧盟法规中对饮用水中氯氧丙烯的最大残留限量(MRL) 0.1 µg/L。
Agilent Measuring Relative % Reflectance of Small Samples in a Cary 50 Spectrophotometer Application Note 该文件介绍了Cary 50光谱仪测量小样品相对%反射率的方法
Agilent Automated Preparation of Simulated Distillation Standards and Samples for ASTM Methods D2887, D7213, D7398 and D6352 using the 7693A System with Easy SamplePrep Software Application Note 本手册介绍了使用Agilent 7693A和Easy SamplePrep软件对石油样品进行模拟蒸馏标准和样品的自动制备。
Agilent Automatic Precolumn Derivatization of Amino Acids and Analysis by Fast LC using the Agilent 1290 Infinity LC System Application Note 该文档介绍了Agilent 1290 Infinity LC系统在食品产品中分析水溶性氨基酸的快速、高灵敏度的方法。通过自动化的前柱衍生方法,可以开发出在蛋白质化学和食品分析领域所需的快速、准确的分析方法。
Agilent Basic Performance of the Agilent 7700s ICP-MS for the Analysis of Semiconductor Samples Application Note Agilent 7700s ICP-MS是用于半导体应用的一种高性能质谱仪,具有无与伦比的灵敏度、矩阵耐受性、干扰去除和稳定性。
Agilent Analysis of Low-level Polycyclic Aromatic Hydrocarbons (PAHs) in Rubber and Plastic Articles Using Agilent J&W DB-EUPAH GC column Application Note 1
Agilent Fast analysis of ink dyes using the Agilent 1290 Infinity LC System coupled to Agilent 6140 single quadrupole LC/MS System for forensic analysis of ink pens and markers Application Note 1
AMD Am186TM ED/EDLV High Performance, 80C186- and 80C188-Compatible, 16-Bit Embedded Microcontrollers 这份文档介绍了AMD旗下的Am186TMED/EDLV系列高性能、80C186-和80C188兼容的16位嵌入式微控制器,该系列微控制器具备增强的总线接口、更低的系统成本、更高的性能,并支持3.3V±0.3V的操作
AME, Inc. AME1300 300mA CMOS LDO with RESET Function AME1300是AME公司推出的一款低功耗LDO,具有300mA输出,精度高达±1.5%,并内置微处理器复位监视功能。
Analog Microelectronics, Inc. AME8801/8812/8840 300mA CMOS LDO AME8801/8812/8840是一系列具有低静态电流和低压降的正向线性稳压器,适用于电池应用。它们具有低压降、保证300mA输出、精度高达1.5%、静态电流仅30µA、过温关断、过流保护、短路电流折返、噪声降低旁路电容、省电关断模式等特点。
Agilent A Low Femtogram Target Screen Method for Perfluorinated Compounds in Food Matrices and Potable Water Using the Agilent 6460 Triple Quadrupole LC/MS System Equipped with Agilent Jet Stream Tech 本文档介绍了一种可靠检测低至十亿分之一克(fg)浓度的全氟化碳酸盐(PFCA)和磺酸盐(PFSA)的方法, 该方法不受背景成分干扰,采用在线杂质过滤LC改进。使用该方法可以很好地分离所有全氟化合物。本文对多种PFCA和PFSA进行了分析,均在饮用水中以小于75 fg的柱上浓度检测到(S/N >3)。最敏感的分析物PFHxS、PFDS和PFBS分别在2.6、3.2和5 fg水平检测到。对于整个分析物系列,在猪肝基质提取样品中使用此方法检测限小于600 fg。本研究中,在空白注射中未检测到任何可检测的背景污染。整个系列的线性度高达五个数量级,R2值高于0.996。
Agilent Fast impurity profiling of synthetic oligonucleotides with the Agilent 1290 Infinity LC System and Agilent 6530 Accurate-Mass QTOF LC/MS Application Note 1